SmartBalancer2 – The technology in detail
Measurement channels
  • 2 analog channels (A + B), adjustable
    – Voltage (AC/DC, ±30 V max.)
    – Current (AC/DC, ±30 mA max.)
    – ICP® signal (2 mA, 24 V max.)
    – LineDrive acceleration pick up (10 V, 10 mA max.)
  • 1 digital channel
    1+1 pulse/tachometer
    (Speed, trigger, key phaser)
    – Pulse + AC signals (±26 V)
  • Optical laser reference sensor
Measurement channel parameters
  • Frequency range: 0.5 Hz ... 40 kHz
  • Dynamic: (Measurement/total) 96 dB/136 dB
  • Scanning rate: up to 131 kHz per channel
Measurement range/accuracy
  • Speed: 10 ... 200,000 rpm / ±0.1% or ± 1 rpm
  • Vibration deflection*: 6,000 μm (p-p) / ± 5%
  • Vibration speed*: 6,000 mm/s (p-p) ± 1%
  • Vibration acceleration*: 6,000 m/s² (p-p) / ± 1%
* applies to the LineDrive pick up (1μA/ms-²) and sensors supplying voltage (100 mV/g); Reference point: 159.15 Hz
FFT
  • 2 Hz ... 12,8 kHz at 6.400 lines